Title

THE RELIABILITY OF A NOVEL HEEL-RISE TEST VERSUS GONIOMETRY TO ASSESS PLANTARFLEXION RANGE OF MOTION.

Journal Title

Int J Sports Phys Ther

Publication Date

2-1-2018

Abstract

Background: Ankle plantarflexion (PF) active range of motion (ROM) is traditionally assessed in a non-weight-bearing (NWB) position with a universal goniometer. However, a convenient, reliable, low-cost means of assessing functional PF active ROM in a weight-bearing (WB) position has yet to be established.

Purpose: To compare the intra- and interrater reliability of PF active ROM measurements obtained from a goniometric NWB assessment, and a functional heel-rise test (FHRT) performed in WB.

Study Design: Reliability study.

Methods: Two physical therapy student examiners, blinded to each other's measurements, assessed PF active ROM through a NWB goniometric technique and a FHRT on all subjects within the same test session. Intra- and interrater reliability values were calculated using an intraclass correlation coefficient (ICC

Results: 43 healthy participants (mean ± SD, age: 22.7 ± 1.7 years, height: 1.7 ± 0.1 m, mass: 77.8 ± 17.2 kg) completed testing procedures. The within-session intrarater reliability (ICC

Conclusions: The FHRT was found to have good to excellent intra- and interrater reliability, similar to goniometric measurement. The lack of agreement between these measurements requires further exploration of a WB assessment of ankle PF active ROM.

Level of Evidence: 2b.

Document Type

Article

Disciplines

Physical Therapy | Physiotherapy

Volume

13

Issue

1

First Page

19

Last Page

27

PubMed ID

29484238

ISSN

2159-2896

Share

COinS